Stryker M1 Stretcher

$17,550 + GST
  • One-person operation with roll-in loading and two-stage safety release.
  • Lightweight aluminium frame with high visibility powder coating.
  • Oversized wheels with sealed bearings for smooth transport.
  • Seven height positions and ergonomic lift-and-grip design.
  • Infinite backrest positioning with pneumatic lift assist.

Contact Orange Medical for delivery times.


stryker logo

Share
Description

Stryker M1 Stretcher

The Stryker M1 Stretcher is a lightweight, manual cot designed for efficient patient transport in pre-hospital and hospital settings. Built with a rugged aluminium frame, it supports up to 227 kg and features oversized wheels, ergonomic lift handles, and seven adjustable height positions. Its roll-in loading system includes a two-stage safety release, while colour-coded controls and reflective labelling enhance usability and visibility. The M1 offers infinite backrest positioning, shock and knee gatch settings, and a removable litter for easy cleaning. Optional accessories include IV poles, oxygen holders, and antimicrobial mattresses, making it a versatile and durable solution for emergency care

  • One-person operation
  • Roll-in loading with two-stage load release safety mechanism
  • Oversized wheels with sealed caster and wheel bearings
  • Colour-coded controls
  • High visibility powder-coated frame
  • Light-weight, rugged aluminium construction
  • Shock, knee gatch or flat leg positioning
  • Head-end steer lock system
  • Ergonomic lift-and-grip design
  • Seven height positions
  • Foot-end wheel locks
  • Reflective labelling
  • Release lever guards
  • Removable litter
  • Extendable one-hand release lift handles
  • Integrated bumper system
  • One-hand release, infinite positioning, lift assist, pneumatic backrest
  • One four-point shoulder harness restraint
  • Two lap-belt restraints
  • Lubrication-free maintenance
  • Pressure-washable
  • Includes locking device
Additional information
Weight 40 kg

Videos

 

Preventative Maintenance

Q: What should I know about the cot?

A: Th following:

Product description

The Stryker Model 6100 M-1® Roll-In System is a manual ambulance cot that consists of a platform on a wheeled frame

designed to support and transport a maximum weight of 500 lb (227 kg) in pre-hospital and hospital environments. The

device is collapsible for use in emergency vehicles. The removable litter and patented Steer-Lock System™ provide

enhanced maneuverability. To assist with patient transport, the product features:

  • Lift handles at four corners
  • Patient restraint straps
  • Adjustable pneumatic backrest
  • Optional accessories

For maximum patient comfort, you can select from one of three different litter positions, including:

  • Shock
  • Flat leg
  • Optional knee Gatch

Indications for use

The Stryker Model 6100 M-1 Roll-In System is a non-powered wheeled stretcher, which is intended to support and

transport the entire body of a traumatized, ambulatory, or non-ambulatory human patient (includes infants and adults). In

emergency or transport vehicles, the product:

  • Supports patients in a supine (horizontal) or sitting position
  • Facilitates the transportation of associated medical equipment (i.e. oxygen bottles or IV bags)

This ambulance cot is intended to be used in pre-hospital and hospital environments, in emergency and non-emergency

applications. It is rated to a maximum capacity of 500 lb (227 kg), which is the sum of the patient, mattress, and accessory

weight. Intended operators of the product include:

  • Trained professionals
  • Emergency medical service
  • Medical care center personnel
  • Medical first responders

Ambulance cots are for transportation purposes. They are not intended for extended stay or for use as hospital beds. They

are also not intended for use in devices that change air pressure, such as hyperbaric chambers.


Clinical benefits

  • Cot: patient transport
  • Fastener: support cot for transport
  • Cot and fastener system: support and transport patients

Expected service life

The Stryker Model 6100 M-1 Roll-In System has a five year expected service life under normal use conditions and with

appropriate periodic maintenance.


The yellow and black color scheme is a proprietary trademark of Stryker Corporation.


Errors and omission excepted

Was this article helpful?

Q: What should I know about preventive maintenance?

A: The following:

CAUTION

  • Always use authorized parts to avoid the risk of product damage
  • mproper usage of the product can cause injury to the patient or operator. Operate the product only as described in the manual
  • Do not modify the product or any components of the product. Modifying the product can cause unpredictable operation resulting in injury to patient or operator. Modifying the product also voids its warranty

Establish and follow a maintenance schedule and keep records of the maintenance activity. Remove product from service

before you perform the preventive maintenance inspection. You may need to perform preventive maintenance checks more

often based on your level of product usage. Service only by qualified personnel.

When using maintenance products, follow the directions of the manufacturer and reference all material safety data sheets

(MSDS).

Cleaning

** Disinfecting


Regular inspection and adjustments

The following schedule is a general guide to maintenance. Factors such as weather, terrain, geographical location, and

individual usage will alter the required maintenance schedule. If you are unsure how to perform these checks, contact your

Stryker service technician. If you are in doubt as to what intervals to follow to maintain your product, consult your Stryker

service technician. Check each routine and replace worn parts if necessary.


Every month or two hours

Inspect these items every month or two hours, whichever comes first.


Every three months or six hours

Inspect these items every three months or six hours, whichever comes first.


Every six months or 12 hours

Inspect these items every six months or 12 hours, whichever comes first.


Every 12 months or 24 hours

Inspect these items every 12 months or 24 hours, whichever comes first.

Errors and omission excepted

FAQ

Q: What should i know about disinfecting the cot?

A: In general, when used in concentrations recommended by the manufacturer, you can use either phenolic or quaternary (excluding Virex® TB) type disinfectants. Iodophor type disinfectants are not recommended for use because staining may occur.

The recommended disinfectants for this product’s surfaces include the following:

  • Quaternary (active ingredient – ammonium chloride)
  • Phenolic (active ingredient – o-phenylphenol)
  • Chlorinated bleach solution (use up to UK disinfecting 10,000 ppm available chlorine (941 mL of a 5.25% sodium hypochlorite solution per 4000 mL of water)
  • Alcohol (active ingredient – 70% isopropyl alcohol)

To wipe down the product with disinfectant between uses:

  1. Follow the manufacturer’s dilution recommendations exactly
  2. Apply the recommended disinfectant solution by spray or pre-soaked wipes
  3. Hand wash all surfaces of the product with the recommended disinfectant
  4. Disinfect all exposed surfaces. Pay attention to high contact areas
  5. Follow the disinfecting solution manufacturer’s instructions for appropriate contact time and rinsing requirements
  6. Dry the product thoroughly before returning the product to service

Avoid over saturation. Do not allow the product to remain wet.

Follow the manufacturer’s dilution recommendations for appropriate contact time and rinsing requirements. Follow the chemical manufacturer’s guidelines for proper disinfecting.

Note: Failure to follow the above directions when using these types of cleaners may void this product’s warranty.


CAUTION

  • Do not clean, disinfect, service, or perform maintenance while the product is in use
  • Always wipe the product with clean water and dry after cleaning. Some cleaning products are corrosive in nature and may cause damage to the product. Failure to properly rinse and dry the product leaves a corrosive residue on the surface of the product and may cause premature corrosion of critical components

Errors and omission excepted

Q: Which parts does the cot consist of ?

A: The following:

Errors and omission excepted

Recommended products

Nothing found.

Mission

We exist to challenge the way medical equipment is supplied to our customers in the medical & veterinary sectors. Building trusted, reliable relationships and going that extra mile for our customers. The sweet choice for medical equipment.

Contact

e: [email protected]
m: 0210700420

0
    0
    Your Cart