MedLinket MG1000 Handheld Multi-Gas Analyzer

$5,250 + GST

MedLinket MG1000 Handheld Multi-Gas Analyzer is an anesthesia agent analyzer used to measure EtCO2, FiCO2, RR, EtN2O, FiN2O, EtAA, FiAA.
Please allow 3 – 4 weeks for delivery.


SKU MEDL-MG1000 Categories ,


Share
Description

MedLinket MG1000 Handheld Multi-Gas Analyzer

Main Unit’s Environment Requirement Range

Working:

Temperature: 5°C~50°C; Relative humindity: 0~95%;
Atmosphere Pressure:70.0KPa~106.0KPa

Storage:

Temperature: 0°C~70°C; Relative humindity: 0~95%;
Atmosphere Pressure: 22.0KPa~120.0KPa

Power Specification:

Input Voltage: 12V DC 2.0 A
Input Current: 2.0A

Physical Specification

Main Unit
Weight: 0.65Kg
Dimension: 192mm x 106mm x 44mm

Hardware Specification

TFT Screen
Type: Colorful TFT LCD
Dimension: 5.0 inch

Battery
Quantity: 4
Model: Rechargeable lithium battery 3.7 V
Voltage: 3.7V
Capacity: 2200mAh 10 hours
Working time: 10 Hours
Recharging time: 4 Hours

LED
Patient Alarm Indicator: Two colors: Yellow and Red

Sound Indicator
Loudspeaker: Play alarm voices

Interfaces
Power: 12VDC power socket x 1 MINI USB socket x 1
USB: Mini USB siocket X 1

MedLinket MG1000 Handheld Multi-Gas Analyzer Measurement Specification

Principle: NDIR single beam optics
Sampling Rate: 90mL/min, ±10mL/min
Initialization Time: Waveform displaying in 20 seconds

Range:
CO2: 0~99 mmHg, 0~13 %
N2O: 0~100 VOL%
ISO: 0~6VOL%
ENF: 0~6VOL%
SEV: 0~9VOL%
RR: 2~150 bpm
Apnea Alarm Time:

Resolution
CO2: 0~40 mmHg ±2 mmHg
40 ~99 mmHg ±5% of reading

N2O:  0~100VOL%
±(2.0 vol% +5% of reading)

ISO: 0~6VOL%
±(0.3 vol% +2% of reading)

ENF: 0~6VOL%
±(0.3 vol% +2% of reading)

SEV: 0~8VOL%
±(0.3 vol% +2% of reading)

RR:

±1 bpm 20~60s

MAC value define

  • 1.0MAC: under an atmospheric pressure condition, give a person or animal skin stimulation, 50% of people or animals not body dynamic response or escape reflection occurs, the inhalation anesthetics in alveolar concentration.
  • To achieve 95% of people don’t respond to stimuli, the MAC value should reach to 1.3.
  • When MAC value is 0.4,most patients will wake up.

Anaesthetic agents

Enflurane: 1.68
Isoflurane: 1.16
Sevflurane: 1.71
Halothane: 0.75
N2O: 100%

Notice: Desflurane’s MAC1.0 values differ with age

Age: 18-30 MAC1.0 7.25%
Age: 31-65 MAC1.0 6.0%

 

 

Specialized in getting and transferring life signals

Additional information
Weight 10 kg
Recommended products

Nothing found.

Mission

We exist to challenge the way medical equipment is supplied to our customers in the medical & veterinary sectors. Building trusted, reliable relationships and going that extra mile for our customers. The sweet choice for medical equipment.

Contact

e: [email protected]
m: 0210700420

0