Riester RVS-100 Vital Signs Monitor SpO2 + NIBP + Temp

$3,600 + GST

TheRVS-100 is a versatile vital signs monitior for the busy hospital or clinic. Optional Nellcor or Masimo Oximetry

Filac™ 3000 FasTemp™ probe covers, 4 boxes of 500 probes per case (2000 probes in total)


SKU EC-RVS-100T Categories , ,

Riester logo

Share
Description

Riester RVS-100 Vital Signs Monitor SpO2 + NIBP

Image shown with optional FILAC temp

The Riester RVS-100 is a high-performance vital signs monitor ideally suited for busy departments in hospitals or general practice. The V9 features a touch screen display for ease-of-use.

There are multiple options for the end user to consider, these include:

  • Nellcor Oximax oximetry
  • Masimo SPo2
  • Integrated 50mm printer
  • Medtronic FILAC thermometry

All patient ages are coveed, from neonatal to adult.

There are also various mounting options to help the V9 ft perfectly wityin your workflow:

  • Trolley mount
  • Wall mount
  • or desk sitting.

This model is also manufactured for Riester and known as the RVS-100

Standard Config:

NIBP (adult)
Riester SpO2 (adult)
PR
2500mAh Battery
8″ touch screen

Riester RVS-100 Vital Signs Monitor Specifications

General:

Size and Weight
Size: 125 • 308 •233mm
Weight: f4 kg (Including a lithium battery)

DispIay

Type: 8 ” Color Anti-glare TFT LCD Resolution: 600 • 800 pixels

 

Power suppIy

Input voltage: AC: 100V-240V. 50Hz/60Hz Input power: 80VA

 

Battery

Type: 10.8 V 6600mAh rechargeable lithium ion battery Operating time: > 10 hours
Charge time: 6 h to 100% Standby
Data Storage Clinic Mode:
Patient quantity: 1000
Single patient clinic record number: 1- 5000 Monitor Mode:
Patient quantity: 1
Trend data: resolution 3 Min: can store 9600 hours Alarm events: 100000
NIBP measurement record: 50000

 

Environmental Specifications

Operating Temperature:  (5-40) ”C
Humidity: 85% noncondensing
Atmospheric Pressure: (700 1060) hPa

Transportation and Storage

Temperature:  (-20 +55)
Humidity: 93% noncondensing
Atmospheric Pressure: (500 1060) hPa

PR

Measurement range: 20 250 bpm
Resolution: 1 bpm
Accuracy: +1% or + 1 bpm, whichever is the greater

Masimo SpO2,(Option)

– Measurement range: (0-100)% Resolution: 1%
Accuracy: 2% (70% to 100%)
(aduIt/ped iatric, non-m otion conditions)
+ 3% (70% to 100%)
(neon ate, non-motion conditions)
3% (70% to 100%)
(motion conditions)
Unspecified (0% to 69%)

Nellcor SpO2 (Option) Measurement range: (0 100) %

Resolution: 1%
Accuracy: + 2% (70% 100%) (adult)
+ 3% (70% 100%) neonate
+ 2% (70% 100%) low perfusion
unspecified (0 69)%

NIBP

Technique: Automatic oscillometry Range: Adult: 10-270mmHg
Child: 10-235mmHg Neonate: 10-135mmHg
Accuracy: Static +3 mm Hg
Clinic: Average error: +5 mmHg standard deviation: 18 mmHg
Unit: mmHg. kPa
Pulse rate range: 40-240 bpm

BLT Digital SpOz (standard)

Measurement range (0 100) %
Resolution: 1%
Accuracy: + 2% (70% 100%)
Covidien Filac 3000 Oral Quick Thermometer
Accuracy: Quick Mode: (Oral) +/- 0.3” C (+/-0.6 F) Direct Mode: +/- 0.1” C (+/-0.2″ F)
Measurement Response Time: <4 second Oral
Temperature Range : 30 ” C – 43.0 C (86.0 ” F – 109 ” F)

 

Additional information
Weight10 kg