Description
Riester RVS-100 Vital Signs Monitor SpO2 + NIBP
Image shown with optional FILAC temp
The Riester RVS-100 is a high-performance vital signs monitor ideally suited for busy departments in hospitals or general practice. The V9 features a touch screen display for ease-of-use.
There are multiple options for the end user to consider, these include:
- Nellcor Oximax oximetry
- Masimo SPo2
- Integrated 50mm printer
- Medtronic FILAC thermometry
All patient ages are coveed, from neonatal to adult.
There are also various mounting options to help the V9 ft perfectly wityin your workflow:
- Trolley mount
- Wall mount
- or desk sitting.
This model is also manufactured for Riester and known as the RVS-100
Standard Config:
NIBP (adult)
Riester SpO2 (adult)
PR
2500mAh Battery
8″ touch screen
Riester RVS-100 Vital Signs Monitor Specifications
General:
Size and Weight
Size: 125 • 308 •233mm
Weight: f4 kg (Including a lithium battery)
DispIay
Type: 8 ” Color Anti-glare TFT LCD Resolution: 600 • 800 pixels
Power suppIy
Input voltage: AC: 100V-240V. 50Hz/60Hz Input power: 80VA
Battery
Type: 10.8 V 6600mAh rechargeable lithium ion battery Operating time: > 10 hours
Charge time: 6 h to 100% Standby
Data Storage Clinic Mode:
Patient quantity: 1000
Single patient clinic record number: 1- 5000 Monitor Mode:
Patient quantity: 1
Trend data: resolution 3 Min: can store 9600 hours Alarm events: 100000
NIBP measurement record: 50000
Environmental Specifications
Operating Temperature: (5-40) ”C
Humidity: 85% noncondensing
Atmospheric Pressure: (700 1060) hPa
Transportation and Storage
Temperature: (-20 +55)
Humidity: 93% noncondensing
Atmospheric Pressure: (500 1060) hPa
PR
Measurement range: 20 250 bpm
Resolution: 1 bpm
Accuracy: +1% or + 1 bpm, whichever is the greater
Masimo SpO2,(Option)
– Measurement range: (0-100)% Resolution: 1%
Accuracy: 2% (70% to 100%)
(aduIt/ped iatric, non-m otion conditions)
+ 3% (70% to 100%)
(neon ate, non-motion conditions)
3% (70% to 100%)
(motion conditions)
Unspecified (0% to 69%)
Nellcor SpO2 (Option) Measurement range: (0 100) %
Resolution: 1%
Accuracy: + 2% (70% 100%) (adult)
+ 3% (70% 100%) neonate
+ 2% (70% 100%) low perfusion
unspecified (0 69)%
NIBP
Technique: Automatic oscillometry Range: Adult: 10-270mmHg
Child: 10-235mmHg Neonate: 10-135mmHg
Accuracy: Static +3 mm Hg
Clinic: Average error: +5 mmHg standard deviation: 18 mmHg
Unit: mmHg. kPa
Pulse rate range: 40-240 bpm
BLT Digital SpOz (standard)
Measurement range (0 100) %
Resolution: 1%
Accuracy: + 2% (70% 100%)
Covidien Filac 3000 Oral Quick Thermometer
Accuracy: Quick Mode: (Oral) +/- 0.3” C (+/-0.6 F) Direct Mode: +/- 0.1” C (+/-0.2″ F)
Measurement Response Time: <4 second Oral
Temperature Range : 30 ” C – 43.0 C (86.0 ” F – 109 ” F)