KellyMed  KL8052N Infusion Pump

$1,250 + GST

KellyMed KL8052N is a simple single-channel infusion pump that works with non-dedicated IV sets.

Cost per line is reduced – no contracts.


SKU Kel-KL8052N Categories , , ,


Share
Description

KellyMed  KL8052N Infusion Pump

4.2-inch high-definition LCD colour screen
Double infusion mode option and display( drip rate and volumetric)
Real-time self-check during the startup and infusion process
Bolus and quick drainage function cut infusion and drainage time
Anti-bolus function with three gradings(H,M,L)
Ultrasonic air-in-line detection
9 kinds of Audio-visual alarms ensure further safety
Audio prompt function for unconventional infusion speed guarantees error-free operation
Real-time display of total infused volume, easy for clinical observation
Automatically switch to KVO rate operation upon preset volume is completed
The memory of the last running parameters even under power off
Automatically switch among ml/h, drop/min and time-based
Change the flow rate without stopping the pump
Built-in thermostat: 30-45℃, temperature adjustable
Key locker
Extensive flow rate range, 0.1-1500 ml/h, in0.1 ml/h increments
A rechargeable Ni-MH battery keeps the machine above 5 hours running under 30 m/L
Life span up to above 5 years
IPX3, Class II, Type CF

 

KellyMed  KL8052N Infusion Pump Specifications

Pumping mechanism: Curvilinear peristaltic
Dimensions: 174 x 126 x215 mm (W×D×H)
Weight approximately: 2.5Kg
Waterproof classification: IPX3

IV set & Accuracy

IV set selection: 6 kinds of IV set data selectable and storable
IV set: Compatible with IV set of any standard
VTBI range: 0.1-9999ml
Flow rate: 0.1 ~ 1500ml/h (0.1ml/h increments)
Purge/Bolus rate: 100-1500 ml/h(0.1 ml increments)
Bolus volume: 1-20ml/h(1ml increments)
Infusion accuracy:±3%

Infusion mode:

ml/h
Drop/min
Time-based
Easy mode

KVO rate: 0.1-5ml/h(0.1ml/h increments)
Anti-bolus: Anti-bolus system reduce pressure on sudden release of occlusion
Occlusion Sensitivity: 3 levels: High/ Medium/ Low

 

Alarms

Audible and visual alarm:
9 kinds: Occlusion, air-in-line, Pump door open, infusion completion, low battery, drop rate abnormal, flow rate abnormal, KVO, unattended
Sensitivity of air in line:≤40μL, Ultrasonic detector

Power

Power supply(AC): 220±22/110V(optional), 50/60Hz
Battery(DC): 9.6±1.6V, Ni-MH, rechargeable
Battery /operation/charging: Ni-MH/ 5 hours (at 30ml/h) / more than 8 hours
Power consumption   ≤20VA
Safety classification    Class II, Type CF

Environment

Operation temperature:10~40℃
Working relative humidity: 30~75% (no condensation)
Atmospheric pressure:           700-1060 hpa
Storage temperature  -20~+50
Storage relative humidity: ≤93% RH (no condensation)

Extended function

Built-in thermostat: 30-45℃ adjustable
Wireless management(optional): Central monitoring by Infusion Management System
Standard configured consumables
Packed with pump: 1 pc of IV set
Optional: IV pole

Additional information
Weight 10 kg