Description
KellyMed KL8052N Infusion Pump
4.2-inch high-definition LCD colour screen
Double infusion mode option and display( drip rate and volumetric)
Real-time self-check during the startup and infusion process
Bolus and quick drainage function cut infusion and drainage time
Anti-bolus function with three gradings(H,M,L)
Ultrasonic air-in-line detection
9 kinds of Audio-visual alarms ensure further safety
Audio prompt function for unconventional infusion speed guarantees error-free operation
Real-time display of total infused volume, easy for clinical observation
Automatically switch to KVO rate operation upon preset volume is completed
The memory of the last running parameters even under power off
Automatically switch among ml/h, drop/min and time-based
Change the flow rate without stopping the pump
Built-in thermostat: 30-45℃, temperature adjustable
Key locker
Extensive flow rate range, 0.1-1500 ml/h, in0.1 ml/h increments
A rechargeable Ni-MH battery keeps the machine above 5 hours running under 30 m/L
Life span up to above 5 years
IPX3, Class II, Type CF
KellyMed KL8052N Infusion Pump Specifications
Pumping mechanism: Curvilinear peristaltic
Dimensions: 174 x 126 x215 mm (W×D×H)
Weight approximately: 2.5Kg
Waterproof classification: IPX3
IV set & Accuracy
IV set selection: 6 kinds of IV set data selectable and storable
IV set: Compatible with IV set of any standard
VTBI range: 0.1-9999ml
Flow rate: 0.1 ~ 1500ml/h (0.1ml/h increments)
Purge/Bolus rate: 100-1500 ml/h(0.1 ml increments)
Bolus volume: 1-20ml/h(1ml increments)
Infusion accuracy:±3%
Infusion mode:
ml/h
Drop/min
Time-based
Easy mode
KVO rate: 0.1-5ml/h(0.1ml/h increments)
Anti-bolus: Anti-bolus system reduce pressure on sudden release of occlusion
Occlusion Sensitivity: 3 levels: High/ Medium/ Low
Alarms
Audible and visual alarm:
9 kinds: Occlusion, air-in-line, Pump door open, infusion completion, low battery, drop rate abnormal, flow rate abnormal, KVO, unattended
Sensitivity of air in line:≤40μL, Ultrasonic detector
Power
Power supply(AC): 220±22/110V(optional), 50/60Hz
Battery(DC): 9.6±1.6V, Ni-MH, rechargeable
Battery /operation/charging: Ni-MH/ 5 hours (at 30ml/h) / more than 8 hours
Power consumption ≤20VA
Safety classification Class II, Type CF
Environment
Operation temperature:10~40℃
Working relative humidity: 30~75% (no condensation)
Atmospheric pressure: 700-1060 hpa
Storage temperature -20~+50
Storage relative humidity: ≤93% RH (no condensation)
Extended function
Built-in thermostat: 30-45℃ adjustable
Wireless management(optional): Central monitoring by Infusion Management System
Standard configured consumables
Packed with pump: 1 pc of IV set
Optional: IV pole
Additional information
Weight | 10 kg |
---|