Primedic XD Defibrillator – Pacer

$11,200 + GST

The Primedic XD Range is a robustly build and economic defib for your Triage department or ambulance. AED and Manual operation.
Please allow 4 – 6 weeks for delivery.


SKU PRIM-XD-AED-PACE Categories , , Tag


Share
Description

Primedic XD Defibrillator Range – DefiMonitor XD manual + AED

Code: 97728
Model: DefiMonitor XD AED, PACER

Base Spec:

Manual biphasic external defibrillator, asynchronous / synchronous defibrillation, printer, 6-lead ECG,
external pacer. Defibrillator can be powered by rechargeable battery or mains.

Infornation:

The sophisticated high performance instrument with multifunctional features.

It combines a compact product design, proved and tested in practice with the highest possible degree of safety and user friendly handling.

Range of 8 manual or manual + AED defibrillators with or without SpO2 and external pacer.

Supplied with adult/pediatric paddles, disposable adult Save Pads, connect cable, ECG cable, power cable, 1 tube gel, 1 paper roll.

Size: 33x29x16 cm
Weight: 5.3 kg

Made in Germany.

Primedic XD Defibrillator Range Technical Specifications

Defibrillation:

Wave: biphasic, current controlled impulse
Energy (automatic mode) 140-360 J
Manual energy stages: 5J, 10J, 20J, 30J, 50J, 100J, 200J, 300J, 360J
Charging time: < 6 sec at 200 J
Cardio version: manual activation, QRS marker

 

ECG

Derivation: Eindhoven I, II, III
Goldberger, aVR, aVF, aVL
Patient’s resistance: 23-200 Ohm
Heart rate: 30-300 per min
VF: recogniton
VF recogniton
Analysis time 7-12 sec
VF threshold 200 µV
Asystole threshold < 200 µV
Artefact, Pacemaker detection

Thermal printer

Resolution: 200 dpi
Advance: 25 mm/s, 50 mm/s

TFT LCD blue-mode monitor

115×86 mm (diagonal 5.7″/144 mm)
320×240 pixels

Electrodes

Adhesive electrodes, 3 years shelf life
Cable length 3.5 m Save pads connect

Data backup

Removable memory 2 GB
Data/Voice recording up to 35 h

Power supply

Voltage 90-264 V, 50/60 Hz
Rechargeable Lithium-ion battery: Capacity 2.5 Ah Voltage: 13.2 Vdc
Discharges 160-200 J
Monitoring 5.30 h Charging time: 3.2 h

Resuscitation guidelines

AHA/ERC

Standards

IEC60601-1:1988+A1:1991+A2:1995 (Electrical Safety of Med. Electrical Devices)
IEC60601-1-2:2001 (Electromagnetic compatib.)
IEC60601-1-4:1996+A1:1999 (Programmable electrical medical systems)
IEC60601-2-4:2002 (Defibrillators)
EN1789:2003 (Ambulance standard)
Protection class IP33

 

Additional information
Weight 20 kg
Recommended products