LEPU Neo ECG S120 Tablet

$1,850 + GST

The LEPU Neo ECG S120 Tablet

is a portable unit with a 7″ screen. Ideal for the on-the-go clinician or practice.

Cart Available or clinic-based apps.

Lead time: 3-4 weeks

Available on back-order


SKU LEP-S120 Categories , ,


Share
Description

LEPU Neo ECG S120 Tablet

The Neo ECG S120 tablet is ideal for use between rooms or during home visits. It is easy to operate, portable, and compact. With a high accuracy rate and fast analysis speed, the Neo ECG S120 aids in providing a comprehensive diagnosis.

  • High Accuracy Rate: In tests with 1,000,000 independent MIT data points, the AI-ECG platform achieved an average accuracy rate of 95.2%.
  • High Analysis Speed: The device performs automatic resting ECG analysis in just 1 second, reducing the overall time required for clinical ECG analysis.
  • Comprehensive Diagnosis: Supports 16 types of cardiac classifications and 104 types of ECG diagnostic classifications.
  • 7-inch Screen
  • Includes: Patient cables, USB, ECG clips, and Biotabs.
  • Features: Freeze the ECG waveform on the screen, output files in multiple formats (PDF, BMP, HL7, DICOM, SCP), store, preview, review, edit, export, upload, print, and search patient data.
  • Connectivity: Wireless transmission of ECG data via Wi-Fi and mobile networks, built-in Wi-Fi, and USB ports for data transmission and printing.

Technical features:

  • Main unit HR range 30bpm ~ 300bpm
  • Accuracy ± 1%
  • 9/12 lead synchronous acquisition
  • Analog / Digital Signal (A / D) Conversion 24
  • Bitssampling rate 32000 samples / Sec
  • Common mode rejection ratio ≥140dB (AC filter on) ≥120dB (AC filter off)
  • Time response ≥5s
  • Frequency response 0.01HZ ~ 350HZ (+ 0.4db-3.0db)
  • Sensitivity Auto, 2.5mm / mV, 5 mm / mV, 10 mm / mV, 20 mm / mV, 40 mm / mV, less than ± 5% error
  • AC filter: 50Hz, 60Hz, Off
  • EMG filter: 25Hz, 35Hz, 45Hz, Off
  • ADS filter: 0.01 Hz, 0.05 Hz, 0.32 Hz, 0.67 Hz
  • Low pass filter: 75Hz, 100Hz, 150Hz, 300Hz, Off
  • Paper speed 5mm / s, 6.25mm / s, 10mm / s, 12.5mm / s, 25mm / s and 50mm / s, less than ± 3% error
  • Input impedance ≥100MΩ (10Hz)
  • Input circuit current ≤10nA
  • Calibration voltage 1mV ± 2%
  • Depolarization voltage ± 900mV, ± 5%
  • Noise ≤12.5μV
  • Amplitude quantization 0.95 μV / LSB
  • Recovery time after defibrillation <10s
  • Weight: 0.8Kg
  • The package contains: 10-Lead patient cable 6, faux leather sleeve
Additional information
Weight5 kg

Video