Biolight E65 ECG Machine

$2,100 + GST

A nice ECG on a small footprint, uses 140mm wide Z-fold ECG paper. Features a user freindly touch screen with interpretation.


SKU BLT-E65 Categories , ,

Biolight Meditech logo

Share
Description

Biolight E65 ECG Machine Download Brochure:


E65-new-catalogue.pdf

Biolight E65 ECG Machine Quick Specifications:

12 Channel ECG machine
8″ TFT LCD Touchscreen
Full Alpha Numeric Keyboard
Fixed Memory 800 groups, SD Card extension
Compact design with 210 X 140mm X 20M paper
Direct connect all in one cable (no expensive acquisition box)
Full interpretation with 140 different analysis reports

ECG Machine Specifications:

Size and Weight:-Size: 360mmÅ~276mmÅ~130mm (WÅ~HÅ~D)
Weight: 4.2kg
Display” Type: 8.0″, 800×480 TFT LCD touch screen
Power Supply: Input voltage: AC:100V~240V, 50Hz/60Hz
Input power: 100VA
Earth leakage current: <0.3 mA
Standard: Comply with IEC 60601-1 and IEC 60601-1-2

Battery
Type: Rechargeable lithium-ion battery
Rated Voltage: 11.1V
Capability: 4400mAH
Operating time: Used continuously for 5 hours
(print 500 shares of cardiogram)
Indication of battery capability: on screen

Input/Output Specification
Keyboard: USB keyboard
Standard touch-screen connector (4 lines)
Network connector: RJ-45 (one) TCP/IP; Web function
USB connector: 1 x USB Host connects U disk ,scanner,and printe
1 x USB Device connects PC computer
SD card: SD card(Optional)

Data Storage
Fixed Memory: 800 groups of ECG data
Optional Memory: Flash, SD card or U disk
Storage mode: Background storage automatically
Storage format: PDF, DAT, Dicom, FDA-XML, JPEG

Recorder
Recording way: Thermal dot array
Horizontal resolution:40 dots/mm
Vertical resolution: 8 dots/mm
Recording speed: 5 mm/s,6.25 mm/s,10 mm/s, 12.5 mm/s,25 mm/s,50 mm/s, error:±3%
Paper: : 210mmÅ~140mmÅ~20m (Z type)
Paper type: Folded thermosensitive printing paper
Recording type: more than 10 kind of printing methods:
(Auto:3×4,3×4+1R,3×4+3R,6×2,6×2+1R,12×1, 12×1_V6;Manual : 3 path, 6path, 12path, Rhythm: single-lead, three-leads , R-R: R-R)
Measure and Diagnosis of ECG Waveform
HR range: 30bpm -300bpm
HR precision: ±1bpm (10s average)
Coefficient error: ≤5%, 0.333
Measure info of ECG waveform: P time limit, PR interphase, QRS time limit, QT interphase,QTC interphase, RV5swing, SV1swing, RV6swing, SV2swing, RV5+SV1swing, P axis, QRS axis , T axis
Diagnosis analyze: ≥140 kinds

Display of ECG Collection
Signal input:12-lead, defibrillator-proof, Pacemaker pulse rejection
Degree of protection against electric shock: 4000V,
Type CF applied part
Electrode offset potential: ±600 mV d.c.
Response to frequency: 0.05Hz-200Hz(-3dB)
Baseline filter: On/Off
ECG filter: 25Hz,35Hz,45Hz, Close
Lowpass filter: 75Hz,100Hz,150Hz,200Hz,Close
Frequency filter: Off/On
Gain selection: 2.5,5,10,20, 40,10/5,AGC (mm/mV)
Gain accuracy: ≤5%
Time base selection: 5 mm/s,6.25 mm/s,10 mm/s, 12.5 mm/s,25mm/s, 50mm/s
Input impedance: ≥50MΩ
Current of input loop: ≤15n A
Patients leakage current: ≤10 μ V
CMRR: ≥110 dB (with AC filter open)
Time for response to wave displaying: ≤5s
Time for baseline recovered after switching leads: ≤1s
Defibrillator-proof: 5000V 360J
Recovering time for defibrillator-proof ≤5
Energy reduced ≤10%
Voltage transfer ≤1V
Standard complied with: IEC 60601-2-25

Environmental Specifications
Operating: Temperature: 5℃~40℃
Relative humidity: 25%~95% (non condensing)
Atmospheric pressure: 700hPa~1060hPa
Temperature: -20℃~+55℃
Relative humidity: 25%~95% (non condensing)
Atmospheric pressure: 500hPa~1060 hPa

Additional information
Weight 10 kg

Video

Documents

E65 new catalogue

Recommended products

Nothing found.

Mission

We exist to challenge the way medical equipment is supplied to our customers in the medical & veterinary sectors. Building trusted, reliable relationships and going that extra mile for our customers. The sweet choice for medical equipment.

Contact

e: [email protected]
m: 0210700420

0
    0
    Your Cart
    Your cart is emptyReturn to Shop